What is BCHP?
copper hydroxy-phosphate (BCHP)
BCHP (Copper hydroxy-phosphate) for Pigmen Penandaan Laser and LDS/MID.
Technical owner: Aurexene Materials Engineering Team · Last updated: 2026-07-25
Apa yang Bukan
- BCHP is basic copper hydroxy phosphate, not black carbon, carbon black, or an LDS/MID catalyst by default.
Kapan Tidak Menggunakannya
- Do not use BCHP when the required laser response mechanism, polymer compatibility, color, or process window has not been validated in the target resin.
Ringkasan Pemutaran Intrinsik
- Layar identitas
- Cu2(OH)PO4; Green crystalline powder; orthorhombic copper hydroxyphosphate
- Fitur intrinsik
- BCHP requires source-backed function review before public grade-level positioning. composition, form, processing route, and the linked application requirements.
Kesesuaian aplikasi
Kerangka Seleksi & Validasi
| Pertanyaan Keputusan | Jawaban Tingkat Materi |
|---|---|
| Integration and processing criteria | Required for: Pigmen Penandaan Laser, LDS/MID, and Sistem yang Dapat Dimatangkan dengan Laser. Measure: particle distribution; settling; redispersion; storage stability; moisture exposure. Sample state: final host formulation or part state. Failure signals: Use when evaluating Pigmen Penandaan Laser / LDS/MID / Sistem yang Dapat Dimatangkan dengan Laser formulations or systems.. |
Identitas material dan status spesifikasi
Nilai kemurnian dan kemasan yang disetujui belum dipublikasikan; konfirmasikan saat penawaran atau peninjauan sampel.
| Sifat | Nilai |
|---|---|
| Komposisi | Cu2(OH)PO4 |
| CAS / identity | 12158-74-6 |
| Ukuran partikel | Fine powder; mean size often in sub-10 um range |
| Morfologi | Green crystalline powder; orthorhombic copper hydroxyphosphate |
| Densitas | Approx. 3.6-4.0 g/cm3 true density; 0.4-0.6 g/cm3 loose bulk density |
| Penyimpanan | Wadah kering dan tertutup rapat |
Mengapa Ini Berhasil
| Struktur | Fungsi | Mekanisme |
|---|---|---|
| Copper hydroxy-phosphate; Fine powder | BCHP requires source-backed function review before public grade-level positioning. composition, form, processing route, and the linked application requirements. |
Bandingkan Rute Material
Panduan Teknis
| Panduan Teknis | Ringkasan |
|---|---|
| Balancing Laser Energy, Scan Speed, Layer Thickness, Conversion, and Thermal Damage | Balancing Laser Energy, Scan Speed, Layer Thickness, Conversion, and Thermal Damage — panduan rekayasa berbasis metode untuk Sistem yang dapat dikeraskan dengan laser yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi. |
| Blistering, Delamination, Over-Etching, Carbonization, and Polymer Damage | Blistering, Delamination, Over-Etching, Carbonization, and Polymer Damage — panduan rekayasa berbasis metode untuk LDS/MID yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi. |
| Cleaning, Conditioning, Electroless Copper Deposition, and Subsequent Plating | Cleaning, Conditioning, Electroless Copper Deposition, and Subsequent Plating — panduan rekayasa berbasis metode untuk LDS/MID yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi. |
| Compounding LDS Activators Without Agglomeration, Color Instability, or Mechanical Loss | Compounding LDS Activators Without Agglomeration, Color Instability, or Mechanical Loss — panduan rekayasa berbasis metode untuk LDS/MID yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi. |
| Diagnosing Incomplete Activation, Skipped Plating, and Nonuniform Metal Coverage | Diagnosing Incomplete Activation, Skipped Plating, and Nonuniform Metal Coverage — panduan rekayasa berbasis metode untuk LDS/MID yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi. |
Commercial Availability
Supplier role: Request confirmation
Supply status: Request confirmation
Sample status: Sample availability requires confirmation
Commercial details are not published until the source and verification fields are complete and the Supplier Data Packet is signed by the sales owner, technical reviewer, and resource/compliance owner. Request current grade, form, sample, packaging, and delivery confirmation.
Dokumen dan permintaan
Akses dokumen mengikuti status persetujuan saat ini. File yang tidak disetujui atau tidak tersedia dirutekan ke permintaan dokumen, bukan unduhan publik.
Lembar data teknis
Approved public file
Lembar data keselamatan
Diperlukan persetujuan
Related resources
Grade, Sample & Qualification Support
The Aurexene Materials Engineering Team can review the required form, host system, formulation or process, target, sample quantity, volume and timeline, and the grade-specific evidence needed before qualification.
Ulasan Kemampuan laboratorium untuk evaluasi sampel dan dukungan kualifikasi, atau Kemampuan produksi untuk peningkatan skala, kualitas, dokumentasi, dan dukungan pasokan.
Request BCHP Sample / Qualification Review