What is BCHP?

copper hydroxy-phosphate (BCHP)

BCHP (Copper hydroxy-phosphate) for Pigmen Penandaan Laser and LDS/MID.

Technical owner: Aurexene Materials Engineering Team · Last updated: 2026-07-25

copper hydroxy-phosphatecopper hydroxy phosphateBasic Copper MolybdateMo-Doped BCHPlaser pigmentlaser marking additive

Apa yang Bukan

  • BCHP is basic copper hydroxy phosphate, not black carbon, carbon black, or an LDS/MID catalyst by default.

Kapan Tidak Menggunakannya

  • Do not use BCHP when the required laser response mechanism, polymer compatibility, color, or process window has not been validated in the target resin.

Ringkasan Pemutaran Intrinsik

Layar identitas
Cu2(OH)PO4; Green crystalline powder; orthorhombic copper hydroxyphosphate
Fitur intrinsik
BCHP requires source-backed function review before public grade-level positioning. composition, form, processing route, and the linked application requirements.

Kesesuaian aplikasi

Kerangka Seleksi & Validasi

Pertanyaan KeputusanJawaban Tingkat Materi
Integration and processing criteriaRequired for: Pigmen Penandaan Laser, LDS/MID, and Sistem yang Dapat Dimatangkan dengan Laser. Measure: particle distribution; settling; redispersion; storage stability; moisture exposure. Sample state: final host formulation or part state. Failure signals: Use when evaluating Pigmen Penandaan Laser / LDS/MID / Sistem yang Dapat Dimatangkan dengan Laser formulations or systems..

Identitas material dan status spesifikasi

Nilai kemurnian dan kemasan yang disetujui belum dipublikasikan; konfirmasikan saat penawaran atau peninjauan sampel.

SifatNilai
KomposisiCu2(OH)PO4
CAS / identity12158-74-6
Ukuran partikelFine powder; mean size often in sub-10 um range
MorfologiGreen crystalline powder; orthorhombic copper hydroxyphosphate
DensitasApprox. 3.6-4.0 g/cm3 true density; 0.4-0.6 g/cm3 loose bulk density
PenyimpananWadah kering dan tertutup rapat

Mengapa Ini Berhasil

StrukturFungsiMekanisme
Copper hydroxy-phosphate; Fine powderBCHP requires source-backed function review before public grade-level positioning. composition, form, processing route, and the linked application requirements.

Bandingkan Rute Material

Panduan Teknis

Panduan TeknisRingkasan
Balancing Laser Energy, Scan Speed, Layer Thickness, Conversion, and Thermal DamageBalancing Laser Energy, Scan Speed, Layer Thickness, Conversion, and Thermal Damage — panduan rekayasa berbasis metode untuk Sistem yang dapat dikeraskan dengan laser yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi.
Blistering, Delamination, Over-Etching, Carbonization, and Polymer DamageBlistering, Delamination, Over-Etching, Carbonization, and Polymer Damage — panduan rekayasa berbasis metode untuk LDS/MID yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi.
Cleaning, Conditioning, Electroless Copper Deposition, and Subsequent PlatingCleaning, Conditioning, Electroless Copper Deposition, and Subsequent Plating — panduan rekayasa berbasis metode untuk LDS/MID yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi.
Compounding LDS Activators Without Agglomeration, Color Instability, or Mechanical LossCompounding LDS Activators Without Agglomeration, Color Instability, or Mechanical Loss — panduan rekayasa berbasis metode untuk LDS/MID yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi.
Diagnosing Incomplete Activation, Skipped Plating, and Nonuniform Metal CoverageDiagnosing Incomplete Activation, Skipped Plating, and Nonuniform Metal Coverage — panduan rekayasa berbasis metode untuk LDS/MID yang membahas perilaku struktur–fungsi pada batas material, antarmuka, dan sistem akhir, beserta batas proses, validasi, dan kualifikasi.

Commercial Availability

Supplier role: Request confirmation

Supply status: Request confirmation

Sample status: Sample availability requires confirmation

Commercial details are not published until the source and verification fields are complete and the Supplier Data Packet is signed by the sales owner, technical reviewer, and resource/compliance owner. Request current grade, form, sample, packaging, and delivery confirmation.

Dokumen dan permintaan

Akses dokumen mengikuti status persetujuan saat ini. File yang tidak disetujui atau tidak tersedia dirutekan ke permintaan dokumen, bukan unduhan publik.

Lembar data teknis

Approved public file

View TDS

Related resources

Grade, Sample & Qualification Support

The Aurexene Materials Engineering Team can review the required form, host system, formulation or process, target, sample quantity, volume and timeline, and the grade-specific evidence needed before qualification.

Ulasan Kemampuan laboratorium untuk evaluasi sampel dan dukungan kualifikasi, atau Kemampuan produksi untuk peningkatan skala, kualitas, dokumentasi, dan dukungan pasokan.

Request BCHP Sample / Qualification Review