What is MXene?
MXenes (MXene)
MXene (Ti3C2Tx MXene family) for Conductive Materials and EMI Shielding Materials.
Technical owner: Aurexene Materials Engineering Team · Last updated: 2026-07-26
What It Is Not
- MXene is not graphene; Ti3C2Tx is a surface-terminated two-dimensional transition-metal carbide family.
When Not to Use It
- Do not use MXene when moisture, oxidation, long-storage stability, or surface-termination variability cannot be controlled.
Intrinsic Screening Summary
- Identity screen
- Ti3C2Tx (T = O, H, F, etc.); Two-dimensional flake morphology
- Intrinsic feature
- Published technical reference: "Highly conductive, breathable and magnetic MXene/Fe3O4/PEDOT:PSS coated carbon cloth for high-efficiency electromagnetic interference shielding".
Application Fit
Selection & Validation Framework
| Decision Question | Material-Level Answer |
|---|---|
| Integration and processing criteria | Required for: Conductive Materials, EMI Shielding Materials, ESD Materials, and Photothermal / Electrothermal Systems. Measure: surface resistance; volume resistance; resistance uniformity; particle distribution; settling; redispersion; storage stability; moisture exposure. Sample state: final host formulation or part state. Failure signals: Request approved data. |
Material Identity & Specification Status
Approved values for CAS / identity, Density, and Packaging are not published; confirm them during quotation or sample review.
| Property | Value |
|---|---|
| Composition | Ti3C2Tx (T = O, H, F, etc.) |
| Particle size | Powder: 8.0 µm average; aqueous dispersion: 1-10 µm |
| Morphology | Two-dimensional flake morphology |
| Purity | Aqueous dispersion: 0.5 ± 0.1 wt% |
| Storage | Powder: dry sealed container. Aqueous dispersion: refrigerated storage. |
Why It Works
| Structure | Function | Mechanism |
|---|---|---|
| Ti3C2Tx titanium carbide MXene; MXene phase powder | MXene supports Conductive Materials, EMI Shielding Materials, ESD Materials. | Published technical reference: "Highly conductive, breathable and magnetic MXene/Fe3O4/PEDOT:PSS coated carbon cloth for high-efficiency electromagnetic interference shielding". |
Compare Material Routes
Technical Guides
| Technical Guide | Summary |
|---|---|
| A Dispersion Failure Root-Cause Map from Powder Receipt to Final Part Performance | A Dispersion Failure Root-Cause Map from Powder Receipt to Final Part Performance — a method-conditioned engineering guide for Conductive Plastics & Coatings covering structure-function behavior at the material, interface, and finished-system boundary, process limits, validation, and qualification boundaries. |
| Abrasion and Chemical-Exposure Failure in Functional Surfaces | Abrasion and Chemical-Exposure Failure in Functional Surfaces — a method-conditioned engineering guide for Conductive Plastics & Coatings covering structure-function behavior at the material, interface, and finished-system boundary, process limits, validation, and qualification boundaries. |
| Abrasion, Cleaning, and Chemical-Exposure Damage to ESD Performance | A service-sequence qualification method that links defined abrasion, cleaning chemistry, rinse and dry conditions, surface damage, debris, and mapped ESD performance. |
| Absorption, Reflection, and Multiple-Reflection Contributions to EMI Shielding | Separate incident-power reflection, material absorption, transmission, and internal interference before assigning an EMI shielding mechanism or comparing architectures. |
| Accelerated Settling, Centrifugation, Thermal Cycling, and Freeze-Thaw Tests vs Real Shelf Stability | Accelerated Settling, Centrifugation, Thermal Cycling, and Freeze-Thaw Tests vs Real Shelf Stability — a method-conditioned engineering guide for Conductive Plastics & Coatings covering structure-function behavior at the material, interface, and finished-system boundary, process limits, validation, and qualification boundaries. |
Commercial Availability
Supplier role: Request confirmation
Supply status: Request confirmation
Sample status: Sample availability requires confirmation
Commercial details are not published until the source and verification fields are complete and the Supplier Data Packet is signed by the sales owner, technical reviewer, and resource/compliance owner. Request current grade, form, sample, packaging, and delivery confirmation.
Documents & Inquiry
Document access follows the current approval state. Unapproved or unavailable files route to a document request instead of a public download.
Technical Data Sheet
Approval required
Safety Data Sheet
Request required
Related resources
Grade, Sample & Qualification Support
The Aurexene Materials Engineering Team can review the required form, host system, formulation or process, target, sample quantity, volume and timeline, and the grade-specific evidence needed before qualification.
Review Lab Capabilities for sample evaluation and qualification support, or Production Capabilities for scale-up, quality, documentation, and supply support.
Request MXene Sample / Qualification Review